NeoBiotech Sinus All Kit - Crestal Approach & Lateral Approach
Neobiotech · Sinus Lift Sinus All KitNeo SinusAll Kit Every approach. One kit. The Neo SinusAll Kit brings together the Sinus Crestal Approach Kit (SCA), Sinus Lateral Approach Kit (SLA), and Surgical Kit into a single, organised system. Whether the case calls for crestal or lateral access, the complete instrument set is ready in one tray — without the need to prepare and sterilise separate kits for each procedure. SCA + SLA + Surgical — One Tray Colour-Coded Stoppers · Grouped by Stage Aqua System — Water-Assisted Membrane Detachment Clinical Insight What clinicians are saying Real-world feedback from implantologists using the Sinus All Kit across crestal and lateral sinus elevation procedures. "Having one tray that covers both crestal and lateral approaches has simplified how I plan and set up sinus cases considerably. I used to decide the approach pre-operatively and prepare two separate kits accordingly — now I can start crestal and have the lateral instruments immediately to hand if the case requires a change of plan, all from one autoclave run. The colour-coded stoppers by stage and approach mean my nurses can set up correctly the first time, every time." All-in-One Tray · Approach Flexibility · Theatre Setup "The Aqua System is what made me choose the SinusAll Kit over separating my SCA and SLA sets. Water-assisted membrane detachment through the crestal approach is genuinely different from relying entirely on bone spreaders — you can feel when the membrane lifts uniformly, and the extent is adjustable. Combined with the S-Reamer bone disk safety mechanism, it's the most controlled crestal elevation workflow I've used." Aqua System · Water-Assisted Elevation · Crestal Approach Resources Product Documentation Product Brochure User Guide Article Collection Indications When to use the Sinus All Kit The complete solution for posterior maxillary implant procedures requiring sinus augmentation — covering every approach in a single, organised kit. Crestal Sinus Elevation (SCA) — Posterior maxillary implant sites with sufficient residual bone height for a transcrestal approach — using the S-Reamer, Rotary Elevator, Bone Carrier, Bone Condenser, and Aqua System from the crestal component section. Lateral Window Sinus Elevation (SLA) — Cases where crestal approach is not viable: very thin residual bone, previous membrane rupture, multiple implants, or complex sinus anatomy — using the LS-Reamer, C-Reamer, C-Guide, Sinus Elevator, and Side Cutter. Water-Assisted Membrane Detachment — The Aqua System (Aqua Tap + Aqua Hose Set) provides a controlled, water-pressure method for sinus membrane detachment after crestal perforation — with adjustable extent of elevation via a 3cc syringe. Simultaneous Sinus Augmentation & Implant Placement — Single-stage procedure from sinus elevation through to fixture placement — all implant placement tools (Fixture Driver, Hex Driver) are included in the same tray. Mid-Procedure Approach Change — Where the planned crestal approach cannot be safely completed (membrane at risk, septum, insufficient bone), all lateral approach instruments are immediately available in the same tray without requiring a separate kit. Multiple Sinus Approaches Within a Single Practice — For practices performing both crestal and lateral sinus lifts, the SinusAll Kit eliminates the need to maintain, sterilise, and store two separate sinus kits. One autoclave cycle covers every approach — reducing sterilisation room throughput, assistant setup time, and the cost of maintaining two complete instrument inventories. Design Features One tray. Every approach. Maximum safety. Three design principles that define the Neo SinusAll Kit — each addressing a real challenge in managing complex sinus augmentation case loads. One Tray · Every Sinus Approach One autoclave cycle covers every sinus approach SCA, SLA, and implant placement tools are integrated into a single colour-coded tray. One autoclave run covers every approach, reducing tray preparation time, sterilisation overhead, and the risk of a missing instrument mid-procedure. Whether the case calls for crestal or lateral access, the complete instrument set is immediately to hand from first drill to final implant placement. Designed Around Membrane Safety Bone disk protection — in both approaches In the crestal approach, the S-Reamer forms flat bone chips that cushion the sinus floor, making membrane perforation unlikely even on direct contact. In the lateral approach, the LS-Reamer creates a protective bone disk between the instrument and the mucosa throughout drilling. Both mechanisms are built into the instrument design — not dependent on surgical technique alone. Colour-Coded for Clinical Confidence Instruments grouped by stage — errors minimised Stoppers are colour-differentiated by length — 1–12mm crestal / 1–4mm lateral — to prevent confusion at the tray. Instruments are grouped by procedural stage, so setup is fast and sequence errors are minimised. The Aqua System adds water-assisted membrane detachment via a 3cc syringe, with adjustable detachment extent — an additional layer of safety and precision for the crestal approach. Product Video 4-Week Early Loading After Maxillary Sinus Lift Using the Aqua System A clinical case demonstrating early loading following maxillary sinus lift using the Aqua System of the SCA Kit component within the Sinus All Kit. Clinical Cases Both approaches — documented outcomes Clinical cases demonstrating the Sinus All Kit across the crestal and lateral window approaches. Clinical Case 1 — Crestal Approach (SCA) Crestal sinus elevation using the S-Reamer and Aqua System — implant placement with panoramic X-ray follow-up 1 Incision 2 LS-Reamer 3 Elevate Sinus Membrane 4 Bone Graft 5 Suture 6 Panoramic X-Ray of Implant Placement Clinical Case 2 — Lateral Approach (SLA) Lateral window sinus elevation using LS-Reamer and Sinus Elevators — bone graft, simultaneous implant placement, and panoramic X-ray follow-up 1 #14 and #15 2 LS-Reamer 3 Sinus Elevate 4 Bone Graft 5 Implant Placement 6 Panoramic X-Ray of Implant Placement Kit Components Complete instrument set — three tool groups All instruments for crestal approach, lateral approach, and implant placement are supplied in a single colour-coded tray. Crestal Approach Tool Components Component Function Key Spec S-ReamerSASR28 / SASR32 / SASR36 / SASR39 Perforates sinus inferior cortical wall via crestal approach; bone chips fill reamer to form flat bone disk protecting the membrane Ø2.8 / 3.2 / 3.6 / 3.9 · 1,200 rpm Stopper (Crestal)CDS010–CDS120 Colour-coded depth control for S-Reamer, Depth Gauge, Bone Condenser and other crestal tools. Adds 0.2mm to drill length when attached. 1–12mm, 12 sizes (1mm steps) Depth GaugeSADG01 Measures remaining bone thickness after S-Reamer perforation. Both tip sides are flat, designed to hook inside the sinus wall. Ø2.6 / Ø3.1 · Do not insert more than 1mm beyond residual bone height Bone CarrierJUMB02 Transports and inserts bone graft material into the sinus hole 0.05cc per insertion Bone CondenserSABC01 Keeps graft material in place on the sinus floor via the osteotomy site Ø1.0 · Ø2.2 Aqua System — Aqua TapAQT Self-tapped into the crestal bone after sinus hole formation; connects the Aqua Hose for saline injection into the sinus Attached after drilling; fixed with a ratchet driver Aqua System — Aqua Hose SetAQHST (Valve, Hose, Connector) Water-assisted sinus membrane detachment system; 3cc syringe-based, extent of detachment adjustable by volume of saline injected Inject physiological saline slowly and progressively Lateral Approach Tool Components Component Function Key Spec LS-ReamerSALS640 Creates lateral hole in sinus wall; tapered trunk controls depth; thin bone disk forms between reamer and membrane. Sharp center point prevents slipping. Ø6.5 · Single size · 2,000–5,000 rpm C-Guide ReamerSACG610 Guide drill to prevent slippage and locate accurate position before C-Reamer use Ø6.5 C-ReamerSAC640 Creates circular bone core disk from lateral wall — disk preserved as window cover after suturing. Tapered trunk controls depth without stopper. Ø6.5 · 2,000 rpm Sinus Elevator #1 / #2 / #3SLE01 / SLE02 / SLE03 #1: Initial mesial-distal membrane detachment · #2: Lower lateral wall + sinus floor, medial and posterior elevation · #3: Deep interior membrane detachment Used in sequence: #1 → #2 → #3 Side CutterSTC30 Widens the lateral hole formed by LS-Reamer or C-Reamer laterally Ø3.0 · 1,200 rpm Lateral StopperCDS010–CDS040 Depth control for LS-Reamer, C-Reamer, Side Cutter. Adds 0.7mm to LS/C-Reamer; 1.5mm to Side Cutter when attached. 1–4mm, 4 sizes (1mm steps) Implant Placement Tool Components Component Function Key Spec Fixture DriverISFD15R (Long) · ISFD05C (Contra Angle) Implants the fixture — long ratchet and contra-angle type for various access requirements Long ratchet · Contra Angle Hex DriverHD1215S Connects cover screws, healing abutments, abutment screws, and other components to the implant Hex 1.2 · 15mm Note: Sinus Drill (SAD22–SAD40, Ø2.2–Ø4.0) is not included in the Sinus All Kit and must be purchased separately. Specifications Technical specifications Device type All-in-one maxillary sinus implant surgical kit — SCA + SLA + Surgical instrument set Material Medical grade stainless steel (surgical tools and drivers) Catalog number SAKIT S-Reamer diameters Ø2.8 / Ø3.2 / Ø3.6 / Ø3.9 · 1,200 rpm Crestal Stopper range 1–12mm (12 sizes, colour-coded) LS-Reamer Ø6.5 · Single size · 2,000–5,000 rpm · with copious irrigation C-Reamer / C-Guide Ø6.5 · 2,000 rpm Lateral Stopper range 1–4mm (4 sizes) Side Cutter Ø3.0 · 1,200 rpm Aqua System Aqua Tap (AQT) + Aqua Hose Set (AQHST) — 3cc syringe-based water-assisted membrane detachment Sinus Drill (sold separately) Ø2.2 / 2.8 / 3.2 / 3.7 / 4.0 (SAD22–SAD40) · 1,200 rpm · not included in kit Sterilisation Steam autoclave — Pre-vacuum: 132°C / 2 bar / 3 min / 30 min dry · Gravity: 121°C / 1 bar / 40 min / 30 min dry Sterility Non-sterile medical device — must be sterilised before and after each procedure Manufacturer Neobiotech Co., Ltd — Seoul, Korea Origin Made in Korea Clinical Tips Getting the most from the Sinus All Kit Practical guidance for efficient use of the SCA, SLA, and Surgical components within the single-tray system. 1 Plan your primary approach — but have the alternative ready. The Sinus All Kit's core advantage is immediate access to both approaches in one tray. Decide your primary approach from the CT, but confirm that you know where the lateral instruments are positioned in the tray before starting — so that a mid-procedure approach change is fast and calm rather than disruptive. 2 Use the Aqua System immediately after S-Reamer perforation — before bone spreading. After confirming sinus floor opening with the depth gauge, self-tap the Aqua Tap and connect the Aqua Hose. Inject physiological saline slowly via the 3cc syringe to initiate membrane detachment using water pressure. The extent of detachment is adjustable by volume — start conservatively and increase. This step reduces the mechanical stress on the membrane during subsequent bone spreading. 3 Match S-Reamer and Rotary Elevator diameter to the planned implant size. Both the S-Reamer and Rotary Elevator come in Ø2.8 / 3.2 / 3.6 / 3.9. Choose the diameter that matches the CMI fixture size — S-Reamer diameter is directly related to implant CMI fixation. Using an undersized reamer in a wide fixture case risks inadequate tri-cortical engagement. 4 Keep the lateral stopper separate from the crestal stopper at the tray. The crestal (1–12mm) and lateral (1–4mm) stoppers are colour-coded differently, but both groups are in the same tray. Confirm stopper selection before attaching — connecting a crestal stopper to the LS-Reamer or lateral stopper to the S-Reamer will give an incorrect depth limit. The colour differentiation is designed to prevent this, but a verbal check before drilling is still good practice. 5 Use copious irrigation with every rotary instrument — without exception. The S-Reamer (1,200 rpm), LS-Reamer (2,000–5,000 rpm), Rotary Elevator (80 rpm), and Side Cutter (1,200 rpm) all require continuous saline irrigation during operation. If using an optionally purchased Sinus Drill (SAD22–SAD40, 1,200 rpm), the same irrigation requirement applies. Insufficient irrigation risks bone necrosis at the drill site, membrane thermal injury, and reduced bone disk formation quality. The Aqua Hose Set can supply the crestal site; standard handpiece irrigation applies to the lateral instruments. ⚠ Clinical Notice: The Sinus All Kit is a non-sterile medical device intended for use by dental surgeons who have completed implant procedure training. The kit must be sterilised by steam autoclave before and after each procedure. Hydrogen peroxide is prohibited for cleaning — it damages TIN coating and laser markings. Sinus Drill (SAD22–SAD40) is not included and must be purchased separately. Do not use in patients with uncontrolled systemic disease, active infection, malignancy under radiation treatment, blood clotting disorders, titanium allergy, or unrealistic treatment expectations. Follow AS/NZS sterilisation guidelines. Refer to the Instructions for Use for full indications, contraindications, and handling guidelines.