TP-12 Mini Optical Probe | Smart Meter Pulse Detection
.product-block-list__item--description:has(.tespro-inhand-detail){width:100%!important;max-width:100%!important;flex:0 0 100%!important;clear:both} .product-block-list__item--descr iption:has(.tespro-inhand-detail) .card{border:0!important;background:transparent!important;box-shadow:none!important} .product-block-list__item--description:has(.tespro-inhand-detail) .card__header{display:none!important} .product-block-list__item--description:has(.tespro-inhand-detail) .card__section{padding:0!important} .product-block-list__item--description:has(.tespro-inhand-detail) .rte{margin:0!important} .tespro-inhand-product-detail{display:block!important;width:100%!important;max-width:none!important;grid-column:1/-1!important;flex:0 0 100%!important;margin:34px 0 0!important;clear:both} .product-block-list:has(.tespro-inhand-product-detail),.product-block-list__wrapper:has(.tespro-inhand-product-detail){display:block!important} .product-block-list__wrapper:has(.tespro-inhand-product-detail)::after{content:"";display:block;clear:both} .tespro-inhand-detail{--tespro-green:#7FBE26;--tespro-dark:#111827;--tespro-muted:#5f6b76;color:#1b2630;line-height:1.7} .tespro-inhand-detail *{box-sizing:border-box} .tespro-inhand-tabs{position:sticky;top:0;z-index:4;display:flex;justify-content:center;gap:42px;margin:0 0 46px;border-bottom:1px solid #e5e7eb;background:#fff;overflow-x:auto} .tespro-inhand-tabs a{display:block;padding:20px 0 18px;border-bottom:3px solid transparent;color:#1f2937;font-weight:700;text-decoration:none;white-space:nowrap} .tespro-inhand-tabs a:first-child{border-bottom-color:var(--tespro-green);color:var(--tespro-green)} .tespro-inhand-section{max-width:1180px;margin:0 auto;padding:54px 22px;border-bottom:1px solid #edf1e8} .tespro-inhand-section--overview{padding-top:8px} .tespro-inhand-eyebrow{display:inline-block;margin-bottom:12px;color:var(--tespro-green);font-weight:800;text-transform:uppercase;font-size:13px;letter-spacing:.04em} .tespro-inhand-title{margin:0 0 18px;color:var(--tespro-dark);font-size:38px;line-height:1.15;letter-spacing:0} .tespro-inhand-lead{max-width:820px;margin:0;color:var(--tespro-muted);font-size:18px;line-height:1.8} .tespro-inhand-metrics{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:16px;margin-top:34px} .tespro-inhand-metric{min-height:118px;padding:22px;border:1px solid #dcebd2;background:#f7faf4;border-radius:4px} .tespro-inhand-metric strong{display:block;margin-bottom:8px;color:var(--tespro-green);font-size:12px;text-transform:uppercase;letter-spacing:.04em} .tespro-inhand-metric span{display:block;color:#1f2937;font-size:19px;font-weight:800;line-height:1.35} .tespro-inhand-feature{display:grid;grid-template-columns:1.04fr .96fr;gap:46px;align-items:center} .tespro-inhand-feature + .tespro-inhand-feature{margin-top:54px} .tespro-inhand-feature:nth-child(even) .tespro-inhand-feature__media{order:2} .tespro-inhand-feature img,.tespro-inhand-image{display:block;width:100%;height:auto;border-radius:4px;background:#f4f6f7} .tespro-inhand-feature h3{margin:0 0 14px;color:var(--tespro-dark);font-size:28px;line-height:1.25} .tespro-inhand-feature p{margin:0;color:var(--tespro-muted);font-size:16px;line-height:1.75} .tespro-inhand-spec-table{width:100%;border-collapse:collapse;background:#fff} .tespro-inhand-spec-table th,.tespro-inhand-spec-table td{padding:15px 18px;border:1px solid #e5e7eb;text-align:left;vertical-align:top} .tespro-inhand-spec-table th{width:34%;background:#f7faf4;color:#111827;font-weight:800} .tespro-inhand-downloads{display:flex;flex-wrap:wrap;gap:14px} .tespro-inhand-button{display:inline-flex;align-items:center;justify-content:center;min-height:48px;padding:0 22px;border-radius:3px;background:var(--tespro-green);color:#fff!important;font-weight:800;text-decoration:none!important} .tespro-inhand-faq{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:18px} .tespro-inhand-faq article{padding:22px;border:1px solid #e5e7eb;background:#fff;border-radius:4px} .tespro-inhand-faq h3{margin:0 0 8px;color:var(--tespro-dark);font-size:18px} .tespro-inhand-faq p{margin:0;color:var(--tespro-muted)} @media(max-width:900px){.tespro-inhand-tabs{justify-content:flex-start;gap:28px;padding:0 20px}.tespro-inhand-title{font-size:30px}.tespro-inhand-metrics,.tespro-inhand-feature,.tespro-inhand-faq{grid-template-columns:1fr}.tespro-inhand-feature:nth-child(even) .tespro-inhand-feature__media{order:0}.tespro-inhand-spec-table th{width:auto}.tespro-inhand-spec-table th,.tespro-inhand-spec-table td{display:block}} Description Features Specifications Download Reviews Model TP-12 | Mini Optical Probe TP-12 Mini Optical Probe for Smart Meter Pulse Detection The TP-12 optical scanning probe detects visible light and infrared LED pulses emitted by smart meters, then converts them into electrical pulses for calibration and pulse acquisition. It supports +5 V external power with LED indication and +3.3 V low-consumption battery-powered operation with the LED disabled. ModelTP-12 Power SupplyDC 5 V / DC 3.3 V Pulse FrequencyUp to 5 kHz ProtectionIP54 Product Features Low-Power Optical Pulse Detection for Smart Metering Strong Compatibility TP-12 senses light in various colors and wavelengths, converts optical pulses into electrical pulses, and supports different power modes and connector options for project integration. Flexible Fixed Method The probe supports magnets, 3M double-sided tape and other mounting methods. Double-sided tape is widely used because it is simple to fix and protective for the meter surface. High Sensitivity With a maximum pulse frequency of 5 kHz and a minimum pulse width of 200 ms, TP-12 can detect different light colors with strong anti-interference performance indoors and outdoors. Excellent Performance in Harsh Environments PC enclosure material, optional strong magnetic fixing and long-lasting cable construction help TP-12 remain stable in demanding field conditions. Technical Specifications Metering Equipment Technical Data Product Model TP-12 Product Type Mini optical scanning probe for pulse detection Power Supply DC 5 V / DC 3.3 V optional Power Modes 5 V powered with LED indicator; 3.3 V powered with LED indicator disabled Output Level TTL, with 1 M load to V+ recommended Power Consumption Less than 1 uA in standby; instant pulse current less than 140 uA Cable Length 1 m standard; 2 m / 3 m optional Connector Bare wires without connector standard; customized connector available Enclosure Material PC Operating Temperature -40 C to +70 C Dimensions 22 mm diameter / 17 mm height Weight 16 g Probe Fixture 3M double-sided tape by default; magnetic / stick-on strips optional Protection Class IP54 Product Case Ultra-Low-Power Pulse Acquisition for Battery-Operated Projects A battery-operated smart metering project needed stable optical pulse detection without draining device energy. TP-12's ultra-low standby power, minimal pulse current and dual power connection options support reliable pulse acquisition while protecting battery life. Download Product Documents Download Datasheet Official Product Page FAQ Frequently Asked Questions What is TP-12 used for? TP-12 is used to detect visible and infrared LED pulses from smart meters and convert them into electrical pulses for calibration and pulse acquisition. Does TP-12 support low-power battery operation? Yes. The +3.3 V mode disables the top LED indicator and supports less than 1 uA standby consumption. How is TP-12 fixed to meters? 3M double-sided tape is standard, and magnetic or stick-on strips are available as optional fixtures. Do you offer project pricing? Please contact Sales for a discount and project quotation.
More you might like
Related
Blackmagic Mini Converter - Optical Fiber 12G (No Optical Mo
Related
Blackmagic Design Mini Converter - Optical Fiber 12G (No Opt
Related
Blackmagic CONVMOF12G Mini Converter - Optical Fiber 12G (No
Related