TP-485 RS485 Communication Optical Probe | Smart Meter Interface
.product-block-list__item--description:has(.tespro-inhand-detail){width:100%!important;max-width:100%!important;flex:0 0 100%!important;clear:both} .product-block-list__item--descr iption:has(.tespro-inhand-detail) .card{border:0!important;background:transparent!important;box-shadow:none!important} .product-block-list__item--description:has(.tespro-inhand-detail) .card__header{display:none!important} .product-block-list__item--description:has(.tespro-inhand-detail) .card__section{padding:0!important} .product-block-list__item--description:has(.tespro-inhand-detail) .rte{margin:0!important} .tespro-inhand-product-detail{display:block!important;width:100%!important;max-width:none!important;grid-column:1/-1!important;flex:0 0 100%!important;margin:34px 0 0!important;clear:both} .product-block-list:has(.tespro-inhand-product-detail),.product-block-list__wrapper:has(.tespro-inhand-product-detail){display:block!important} .product-block-list__wrapper:has(.tespro-inhand-product-detail)::after{content:"";display:block;clear:both} .tespro-inhand-detail{--tespro-green:#7FBE26;--tespro-dark:#111827;--tespro-muted:#5f6b76;color:#1b2630;line-height:1.7} .tespro-inhand-detail *{box-sizing:border-box} .tespro-inhand-tabs{position:sticky;top:0;z-index:4;display:flex;justify-content:center;gap:42px;margin:0 0 46px;border-bottom:1px solid #e5e7eb;background:#fff;overflow-x:auto} .tespro-inhand-tabs a{display:block;padding:20px 0 18px;border-bottom:3px solid transparent;color:#1f2937;font-weight:700;text-decoration:none;white-space:nowrap} .tespro-inhand-tabs a:first-child{border-bottom-color:var(--tespro-green);color:var(--tespro-green)} .tespro-inhand-section{max-width:1180px;margin:0 auto;padding:54px 22px;border-bottom:1px solid #edf1e8} .tespro-inhand-section--overview{padding-top:8px} .tespro-inhand-eyebrow{display:inline-block;margin-bottom:12px;color:var(--tespro-green);font-weight:800;text-transform:uppercase;font-size:13px;letter-spacing:.04em} .tespro-inhand-title{margin:0 0 18px;color:var(--tespro-dark);font-size:38px;line-height:1.15;letter-spacing:0} .tespro-inhand-lead{max-width:820px;margin:0;color:var(--tespro-muted);font-size:18px;line-height:1.8} .tespro-inhand-metrics{display:grid;grid-template-columns:repeat(4,minmax(0,1fr));gap:16px;margin-top:34px} .tespro-inhand-metric{min-height:118px;padding:22px;border:1px solid #dcebd2;background:#f7faf4;border-radius:4px} .tespro-inhand-metric strong{display:block;margin-bottom:8px;color:var(--tespro-green);font-size:12px;text-transform:uppercase;letter-spacing:.04em} .tespro-inhand-metric span{display:block;color:#1f2937;font-size:19px;font-weight:800;line-height:1.35} .tespro-inhand-feature{display:grid;grid-template-columns:1.04fr .96fr;gap:46px;align-items:center} .tespro-inhand-feature + .tespro-inhand-feature{margin-top:54px} .tespro-inhand-feature:nth-child(even) .tespro-inhand-feature__media{order:2} .tespro-inhand-feature img,.tespro-inhand-image{display:block;width:100%;height:auto;border-radius:4px;background:#f4f6f7} .tespro-inhand-feature h3{margin:0 0 14px;color:var(--tespro-dark);font-size:28px;line-height:1.25} .tespro-inhand-feature p{margin:0;color:var(--tespro-muted);font-size:16px;line-height:1.75} .tespro-inhand-spec-table{width:100%;border-collapse:collapse;background:#fff} .tespro-inhand-spec-table th,.tespro-inhand-spec-table td{padding:15px 18px;border:1px solid #e5e7eb;text-align:left;vertical-align:top} .tespro-inhand-spec-table th{width:34%;background:#f7faf4;color:#111827;font-weight:800} .tespro-inhand-downloads{display:flex;flex-wrap:wrap;gap:14px} .tespro-inhand-button{display:inline-flex;align-items:center;justify-content:center;min-height:48px;padding:0 22px;border-radius:3px;background:var(--tespro-green);color:#fff!important;font-weight:800;text-decoration:none!important} .tespro-inhand-faq{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:18px} .tespro-inhand-faq article{padding:22px;border:1px solid #e5e7eb;background:#fff;border-radius:4px} .tespro-inhand-faq h3{margin:0 0 8px;color:var(--tespro-dark);font-size:18px} .tespro-inhand-faq p{margin:0;color:var(--tespro-muted)} @media(max-width:900px){.tespro-inhand-tabs{justify-content:flex-start;gap:28px;padding:0 20px}.tespro-inhand-title{font-size:30px}.tespro-inhand-metrics,.tespro-inhand-feature,.tespro-inhand-faq{grid-template-columns:1fr}.tespro-inhand-feature:nth-child(even) .tespro-inhand-feature__media{order:0}.tespro-inhand-spec-table th{width:auto}.tespro-inhand-spec-table th,.tespro-inhand-spec-table td{display:block}} Description Features Specifications Download Reviews Model TP-485 | RS485 Communication Optical Probe TP-485 Series RS485 Optical Probe for Smart Meter Communication The TP-485 Series Optical Probe is designed with an RS485 interface for communication with electric meters and heat meters. It supports multiple meter protocols, high-speed transparent transmission and customizable connectors for utility metering projects. ModelTP-485 Series InterfaceRS485 Baud Rate300-115200 bps ProtectionIP54 Product Features RS485 Optical Communication for Multi-Protocol Metering Strong Compatibility Compatible with many brands and types of meters, TP-485 supports IEC 62056-21, ANSI, ANSI-Type2 and DL/T-645 protocol variants for broad metering applications. Ultra-High Speed Communication The probe supports communication rates from 300 to 115200 bps and uses transparent transmission mode for easier integration with instruments and meter systems. Excellent Performance in Harsh Environments 100% PC enclosure material, strong magnetic adhesion and a soft durable cable help the probe remain reliable in field operating conditions. Customization Support Connector type, cable length and model options can be customized to fit project requirements, with OEM/ODM support available for utility deployments. Technical Specifications Metering Equipment Technical Data Product Model TP-485 Series Communication Interface RS485 Supported Standards IEC 62056-21 / ANSI / ANSI-Type2 / DL/T-645 Sub-Models TP-485-IEC: IEC 62056-21 Mode C and E; TP-485-ANSI-N: ANSI C12.18; TP-485-ANSI-S: ANSI C12.18-2006 Type2; TP-485-IR645: DL/T-645-97/07 Maximum Baud Rate 57600 bps in normal operation; maximum 115200 bps available Connector Aviation plug / customized connector Sensor Light Wavelength ~900 nm Cable Length 2 m standard; 3 m / 4 m / 5 m optional Fastening Strong magnetic adhesion in accordance with IEC 62056-21 Magnet Holding Power N40 / N52 optional Operating Temperature -40 C to +70 C Dimensions Optical port 32 mm diameter / L45 x H30 mm Weight 88 g Enclosure Material PC Protection Class IP54 Product Case Direct RS485 Optical Connection for Utility Meter Systems TP-485 helps utility teams connect optical meter interfaces to RS485-based platforms without bulky converters or protocol changes. Its native RS485 design supports stable field communication for electric and heat meter projects. Download Product Documents Download Datasheet Official Product Page FAQ Frequently Asked Questions What is TP-485 used for? TP-485 is used for RS485 optical communication with electric meters and heat meters in utility metering systems. Which protocols are supported? The series supports IEC 62056-21, ANSI C12.18, ANSI C12.18-2006 Type2 and DL/T-645 variants depending on sub-model. Can the connector be customized? Yes. Aviation plug is available and customized connectors can be supplied for project requirements. Do you offer project pricing? Please contact Sales for a discount and project quotation.
More you might like
Related
RS232 to RS485 Communication Drivers & Converters, 485C RS23
Related
RS-485 Pump Heater Remote Communication Cable 4-Wire 22/4 Gr
Related
Schneider Electric-TPCCOM16-TransferPacT - communication Mod
Related