VACUUBRAND VACUU-Select Complete Benchtop Controller Upper Measuring Limit 810 torr Lower Measuring Limit 0.1 torr Accuracy Less than +/- 1 mbar/hPa/torr Features Supplied complete and ready for use, including integrated valve and common hose connections Predefined vacuum applications and automatic boiling point detection saves time Simple setup - connect VACUU·SELECT in-line between pump and vacuum application Integrated vent valve allows inert gas connection Integrated check valve minimizes interaction with other applications on the same vacuum supply VACUUBRAND is a Platinum Service Member Platinum recognition is reserved for approximately 10% of our manufacturer partners and is earned through above-and-beyond performance, service, and customer care—not through purchase or sponsorship. A partner you can count on. Backed by dependable support. OutstandingWarranty Support Coverage that provides real peace of mind. QuickTurnaround Fast answers and efficient resolutions. DependableService Consistent support from start to finish. Backed for theLong Run Continued support throughout ownership. The VACUU·SELECT complete controller provides enhanced process efficiency to applications supported by a vacuum source such as a basic pump or a powerful vacuum network. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run pre-defined applications at the touch of a button, or create your own application with simple drag-and-drop editing. The controller is available as a benchtop unit, ready for mounting on lab scaffolding, or as a built-in version for lab casework. The integrated controller includes the VACUU·SELECT vacuum controller, a check valve, and a chemical-resistant solenoid isolation valve. The ceramic vacuum sensor and venting valve are built right into the body of the VACUU·SELECT controller. The compact unit is easy to install and setup. With its intuitive, application-based interface, the controller offers predefined vacuum processes for all common laboratory applications. In the case of solvent evaporation, it detects the boiling pressure and then holds the pressure level stable using two-point control. INCLUDED:The VACUUBRAND VACUU-Select Complete Benchtop Controller includes: VACUU·SELECT complete controller bench-top device Solenoid valve Non-return valve Integrated ceramic diaphragm vacuum sensor Venting valve Power supply Operator's Manual Manufacturer's Documentation 2 Year Manufacturer's Warranty VACUUBRAND VACUU-Select Complete Benchtop Controller Specifications Upper measuring limit in mbar/hPa 1080 mbar Upper measuring limit in torr 810 torr Lower measuring limit in mbar/hPa 0.1 Lower measuring limit in torr 0.1 torr Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr Vacuum sensor VACUU·SELECT Sensor Temperature coefficient < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K Vacum connection Hose nozzle DN 6/10 mm Venting valve Integrated, hose nozzle DN 4-5 mm Lower ambient temperature (storage) -10 °C Upper ambient temperature (storage) 60 °C Lower ambient temperature (operation) 10 °C Upper ambient temperature (operation) 40 °C Max. media temperature for continuous operation 40 °C Max. media temperature short term 80 °C Material of outer housing Robust plastic housing with good chemical resistance Protection class IEC 60529 IP 40 Protection class UL50E Type 1 Protection class front side IEC 60529 IP 41 Protection class UL50E front side Type 2 Dimension L in mm 191 mm Dimension B in mm 127 mm Dimension H in mm 187 mm Weight 2 kg Max. current for VACUU BUS (24V DC) 4 A Cable length connection in m 2 m Interface Ethernet (RJ45): Modbus TCP / USB (Type A): Data transfer, software update, RS-232 (additional adapter required) NRTL certification Yes Items supplied VACUU·SELECT complete controller bench-top device, with solenoid valve, non-return valve, integrated ceramic diaphragm vacuum sensor and venting valve. With power supply, ready to use, with manual. Comparison of Models Specification VACUU-Select Benchtop VACUU-Select Scaffold VACUU-Select + VACUU-VIEW + VSP 3000 (KF DN 16) VACUU-Select + VACUU-VIEW + VSP 3000 (KF DN 25) VACUU-Select + VSP 3000 (KF DN 16) VACUU-Select + VSP 3000 (KF DN 25) Upper Measuring Limit (mbar/hPa) 1080 1080 1100 1100 1000 1000 Lower Measuring Limit (mbar/hPa) 0.1 0.1 1 x 10-3 1 x 10-3 1 x 10-3 1 x 10-3 Accuracy of Measurement < ± 1 mbar/hPa/torr < ± 1 mbar/hPa/torr ± 15% of indicated value (0.01-5 mbar) / ±3 mbar (> 5 mbar) ± 15% of indicated value (0.01-5 mbar) / ±3 mbar (> 5 mbar) ± 15% of indicated value (0.01-5 mbar/hPa/torr) ± 15% of indicated value (0.01-5 mbar/hPa/torr) Vacuum Sensor VACUU·SELECT VACUU·SELECT VACUU·VIEW extended VACUU·VIEW extended VSP 3000 VSP 3000 Vacuum Connection Hose nozzle DN 6/10 mm Hose nozzle DN 6/10 mm Small flange KF DN 16 / hose nozzle DN 10 mm Small flange KF DN 25 / hose nozzle DN 15 mm Small flange KF DN 16 / hose nozzle DN 10 mm Small flange KF DN 25 / hose nozzle DN 15 mm Dimensions LxBxH (mm) 191 x 127 x 187 152 x 127 x 188 152 x 127 x 41 152 x 127 x 41 152 x 127 x 41 152 x 127 x 41 Weight (kg) 2 2 0.6 0.6 0.6 0.6 .comparison-table tr td:nth-child(2) { background-color: #fffacd; } Downloads Technical Specification Download Operator's Manual Download Request a Formal Quote