The Valleylab Force FX™ is an isolated output electrosurgical generator that enables surgeons to perform precise cutting, desiccation, and fulguration of tissue during procedures. The device supports both bipolar and monopolar electrosurgery, and can be controlled using a handset or footswitch. The receptacles are clearly marked to ensure proper accessory connection, and the user is notified through indicators when the generator is activated. With adjustable volume for activation tones and the ability to reset previous mode and power settings, the Covidien Force FX™ provides a versatile surgical experience. Additionally, the device features an RF activation port, RS-232 serial port, and expansion port for expanded functionality. For optimal performance, the Force FX™ can be used alongside the Valleylab Force GSU System and the Valleylab Electroshield Monitor. REM™ Contact Quality Monitoring System Measurement Frequency: 80 kHz ± 10 kHz Measurement Current: Less than 10 µA Acceptable Resistance Ranges: –REM™ pad – 5-135 ohms –Non-REM™ pad – less than 20 ohms Acceptance range is 5-135 ohms after REM PolyHesive II return electrode is applied. Adaptive REM™ REM™ trip is baseline impedance plus 40%. For example, if the baseline impedance is 30 ohms, the upper level trip approximately 42 ohms. If the pad-patient impedance falls below the baseline impedance, a new baseline is established. Output Characteristics Bipolar Precise Mode: Maximum P-P Voltage: 450 Rated Load (OHMS): 100 Maximum Power (Watts): 70 Crest Factor* (Typical): 1.5 Standard Mode: Maximum P-P Voltage: 320 Rated Load (OHMS): 100 Maximum Power (Watts): 70 Crest Factor* (Typical): 1.5 Macro Mode: Maximum P-P Voltage: 750 Rated Load (OHMS): 100 Maximum Power (Watts): 70 Crest Factor* (Typical): 1.5 Monopolar Coag Desiccate Mode: Maximum P-P Voltage: 3500 Rated Load (OHMS): 500 Maximum Power (Watts): 120 Crest Factor* (Typical): 5 Fulg. High Crest Factor* Mode: Maximum P-P Voltage: 8500 Rated Load (OHMS): 500 Maximum Power (Watts): 120 Crest Factor* (Typical): 7.0 Fulg. Low Crest Factor *Mode: Maximum P-P Voltage: 6900 Rated Load (OHMS): 500 Maximum Power (Watts): 120 Crest Factor* (Typical): 5.5 Spray Mode: Maximum P-P Voltage: 9000 Rated Load (OHMS): 500 Maximum Power (Watts): 120 Crest Factor* (Typical): 8 CEM™ Mode Monopolar Cut (Low): Maximum P-P Voltage: 1000 Rated Load (OHMS): 300 Maximum Power (Watts): 100 Crest Factor* (Typical): 1.5 Monopolar Coag (Dessicate): Maximum P-P Voltage: 3500 Rated Load (OHMS): 500 Maximum Power (Watts): 70 Crest Factor* (Typical): 5 * Crest Factor is an indicator of a waveform’s ability to coagulate without cutting