Description VIAIR Mounted Systems (VMS) are high-performance onboard air systems designed to provide high CFM flow and fast tire fill with unsurpassed durability. These kits come with a single compressor, wiring harness, a high-quality remote air chuck kit, and all necessary hardware and components to install a fully functioning system. VMS can be used for tire inflation, air tools, air horns, air lockers, air bags, and inflatables of all kinds. Kits are also available in a dual configuration.400C (150 PSI): Ideal for tire inflation management and any inflation tasks where 150PSI is needed. Reliable, fills fast in a very compact package. 100% Duty Cycle @ 40 PSI. 444C (200 PSI): Ideal for tire inflation management, air suspension, and general needs where 200PSI is needed. Reliable and affordable. 100% Duty Cycle @ 100PSI. 485C (200 PSI): One of our finest 12 volt compressors available. Well-suited for tire pressure management, air suspension, air horns, and other general compressed air needs. One of the only compressors that has 100% Duty Cycle @ 200PSI. Specifications 400C SPECSCFM: 2.62 @ 0 PSI12-VoltPermanent Magnetic MotorDuty Cycle: 33% @ 100 PSIDuty Cycle: 100% @ 40 PSIMax. Working Pressure: 150 PSIMax. Air Tank Size: 5.0 GallonMax. Amp Draw: 30-AmpsIngress Protection Rating: IP67Max Ambient Temp: +158°FMin Ambient Temp: -40°FDimensions:9″L x 4″W x 6.75″HNet Weight: 8.65 lbs. 444C SPECSCFM: 2.12 @ 0 PSI12-VoltPermanent Magnetic MotorDuty Cycle: 100% @ 100 PSIDuty Cycle: 50% @ 200 PSIMax. Working Pressure: 200 PSIMax. Air Tank Size: 5.0 GallonMax. Amp Draw: 23-AmpsIngress Protection Rating: IP67Max Ambient Temp: +158°FMin Ambient Temp: -40°FDimensions:10.87″L x 4.2″W x 7.06″HNet Weight: 10.80 lbs. 485C SPECSCFM: 2.24 @ 0 PSI12-VoltPermanent Magnetic MotorDuty Cycle: 100% @ 200 PSIMax. Working Pressure: 200 PSIMax. Air Tank Size: 5.0 GallonMax. Amp Draw: 23-AmpsIngress Protection Rating: IP67Max Ambient Temp: +158°FMin Ambient Temp: -40°FCompressor Dimensions:10.63″L x 4.1″W x 6.44″HCompressor’s Net Weight: 11.10 lbs. PLEASE NOTE:Use thread sealant for proper installation. Thread tape is not recommended. Properly sealed, recommended torque for 1/8” is 10 ~ 11 ft. lbs. Recommended torque for 1/4” and 3/8” is 16 ~ 18 ft. lbs. Performance 400C 12-VOLT COMPRESSOR - Supply Voltage 13.8 Volts PSI CFM A BAR LPM A 0 2.62 16 0 74 16 10 2.39 18 1.0 65 20 20 2.21 20 2.0 60 23 30 2.11 22 3.0 56 25 40 2.01 24 4.0 53 27 50 1.93 25 5.0 49 28 60 1.84 26 6.0 46 28 70 1.73 27 7.0 42 28 80 1.65 27 8.0 28 28 90 1.52 27 9.0 35 27 100 1.45 27 10.0 31 27 110 1.35 27 120 1.26 27 130 1.19 27 140 1.08 27 150 1.01 26 444C 12-VOLT COMPRESSOR - Supply Voltage 13.8 Volts PSI CFM A BAR LPM A 0 2.12 16 0.0 60 10 10 1.72 12 1.0 47 13 20 1.61 14 2.0 43 15 30 1.53 15 3.0 41 16 40 1.48 16 4.0 55 17 50 1.41 17 5.0 36 18 60 1.33 17 6.0 33 19 70 1.28 18 7.0 27 19 80 1.20 18 8.0 28 19 90 1.13 19 9.0 25 19 100 1.01 19 10.0 23 19 110 0.95 19 11.0 20 18 120 0.94 19 12.0 17 17 130 0.88 19 13.0 15 16 140 0.82 19 14.0 12 15 150 0.77 18 160 0.72 18 170 0.65 18 180 0.57 17 190 0.49 16 200 0.45 16 485C 12-VOLT COMPRESSOR - Supply Voltage 13.8 Volts PSI CFM A BAR LPM A 0 2.24 12 0.0 70 12 10 1.84 14 1.0 47 16 20 1.75 16 2.0 47 16 30 1.67 17 3.0 44 18 40 1.61 18 4.0 41 20 50 1.54 19 5.0 38 21 60 1.47 20 6.0 35 21 70 1.42 21 7.0 32 22 80 1.36 21 8.0 29 22 90 1.30 22 9.0 27 22 100 1.23 22 10.0 25 23 110 1.17 22 11.0 22 22 120 1.11 22 12.0 21 21 130 1.06 22 13.0 21 21 140 1.01 23 14.0 21 21 150 0.97 22 160 0.92 22 170 0.88 22 180 0.84 21 190 0.77 21 200 0.73 21 Fill Rates 400C TIRE FILL RATE 35″ x 12.5″ FILL RATE 0 to 40 PSI 7 min. 09 sec. (± 15 sec.) 10 to 40 PSI 5 min. 29 sec. (± 10 sec.) 37″ x 12.5″ FILL RATE 0 to 40 PSI 8 min. 15 sec. (± 15 sec.) 10 to 40 PSI 6 min. 19 sec. (± 15 sec.) 400C TANK FILL RATE 2.5 GALLON TANK FILL RATE 0 to 145 PSI 2 min. 27 sec. (± 05 sec.) 110 to 145 PSI 55 sec. (± 05 sec.) 5.0 GALLON TANK FILL RATE 0 to 145 PSI 4 min. 50 sec. (± 10 sec.) 110 to 145 PSI 1 min. 40 sec (± 05 sec.) 444C TIRE FILL RATE 35″ x 12.5″ FILL RATE 0 to 40 PSI 8 min. 37 sec. (± 15 sec.) 10 to 40 PSI 6 min. 31 sec. (± 15 sec.) 37″ x 12.5″ FILL RATE 0 to 40 PSI 9 min. 43 sec. (± 15 sec.) 10 to 40 PSI 7 min. 29 sec. (± 15 sec.) 444C TANK FILL RATE 2.5 GALLON TANK FILL RATE 0 to 200 PSI 5 min. 02 sec. (± 10 sec.) 165 to 200 PSI 1 min. 30 sec. (± 05 sec.) 5.0 GALLON TANK FILL RATE 0 to 200 PSI 10 min. 52 sec. (± 15 sec.) 165 to 200 PSI 3 min. 10 sec (± 10 sec.) 485C TIRE FILL RATE 35″ x 12.5″ FILL RATE 0 to 40 PSI 8 min. 21 sec. (± 15 sec.) 10 to 40 PSI 6 min. 27 sec. (± 15 sec.) 37″ x 12.5″ FILL RATE 0 to 40 PSI 9 min. 36 sec. (± 15 sec.) 10 to 40 PSI 7 min. 22 sec. (± 15 sec.) 485C TANK FILL RATE 2.5 GALLON TANK FILL RATE 0 to 200 PSI 4 min. 50 sec. (± 10 sec.) 165 to 200 PSI 1 min. 15 sec. (± 05 sec.) 5.0 GALLON TANK FILL RATE 0 to 200 PSI 9 min. 45 sec. (± 15 sec.) 165 to 200 PSI 2 min. 25 sec (± 10 sec.) Product Resources Dimensional-Drawing 400DB-400DC-400DB01-400DC01 Dimensional-Drawing 444DB-444DC-444DB01-444DC01 User-Manual 444DB-444DC User-Manual 485DB-485DP