DESCRIPTION Voltmeter with Bluetooth interface / Current measurement 0 ... 1000 A AC/DC / Temperature measurement / NCV test / Clamp opening 34 mm (1.3") / Measuring rate of 3 Hz /Optionally expandable with Rogowski coil for 3000 A AC / Automatic switch-off The voltmeter has a measuring range of 0… 1000 A AC/DC. The current is measured inductively using the clamp on the measuring device. Live supply lines with a diameter of up to 32 mm (1.2") can be connected to the clamp meter. With the optional Rogowski coil, the measuring range of the clamp meter can be extended to up to 3000 A AC. The clamp meter has sub-functions for current measurement. The inrush current can be measured with the clamp meter. This is a particularly important function, as motors such as those installed in ventilation systems or hall lighting require a particularly high current when switched on.In addition to current measurement, the voltmeter can also measure voltages from 0… 1000 V AC/DC, resistances, frequencies and capacitances. The functions can be set using the rotary selector switch on the clamp meter. With the NCV function, the clamp meter can be used to determine the absence of voltage without contact. As soon as a voltage of 150 V AC is applied, this is indicated by an additional red LED. This function is active for every measuring function selected using the rotary selector switch. An LED lamp is integrated in the clamp meter for optimal illumination of the measuring point.The voltmeter can be connected to an Android or iOS device via the Bluetooth interface. With the free app for the clamp meter, the measured values can be displayed, saved and further processed. The clamp meter thus covers a wide range of measuring tasks due to the multitude of functions. HIGHLIGHTS - Measuring range 0 ... 1000 A AC/DC- Bluetooth interface- Inrush current measurement- Not Connected Voltage function- LC colour display- Optionally with ISO certificate SPECIFICATION DC voltage Measuring range 600.0 mV DC Resolution 0.1 mV DC Accuracy ±(0.5 % + 8 digits) Measuring range 6.000 V DC Resolution 0.001 V DC Accuracy ±(1.5 % + 5 digits) Measuring range 60.00 V DC Resolution 0.01 V DC Accuracy ±(1.5 % + 5 digits) Measuring range 600.0 V DC Resolution 0.1 V DC Accuracy ±(1.5 % + 5 digits) Measuring range 1000 V DC Resolution 1 V Accuracy ±(1.5 % + 5 digits) Input impedance >10 MΩ Overvoltage protection 1000 V AC/DC AC voltage Measuring range 6.000 V AC Resolution 0.001 V AC Accuracy ±(1.5 % + 5 digits) Measuring range 60.00 V AC Resolution 0.01 V AC Accuracy ±(1.5 % + 5 digits) Measuring range 600.0 V AC Resolution 0.1 V AC Accuracy ±(1.5 % + 5 digits) Measuring range 1000 V AC Resolution 1 V AC Accuracy ±(1.5 % + 5 digits) Peak value (PEAK) accuracy ±10 % Peak value (PEAK) response time 1 ms Input impedance >10 MΩ Overvoltage protection 1000 V AC/DC The accuracy relates to a measuring range of 10 ... 100 %with a sine wave. Low pass filter (LowZ)(50 ... 400 Hz) Measuring range 6.000 V AC Resolution 0.001 V AC Accuracy ±(3.0 % + 40 digits) Measuring range 60.00 V AC Resolution 0.01 V AC Accuracy ±(3.0 % + 40 digits) Measuring range 300.0 V AC Resolution 0.1 V Accuracy ±(3.0 % + 40 digits) Input impedance 10 MΩ Direct current Measuring range 600.0 A DC Resolution 0.1 A DC Accuracy ±(2.5 % + 5 digits) Measuring range 1000 A DC Resolution 1 A DC Accuracy ±(2.8 % + 5 digits) Overvoltage protection 1000 A DC Alternating current(50 ... 60 Hz) Measuring range 600.0 A AC Resolution 0.1 A AC Accuracy ±(2.5 % + 5 digits) Measuring range 1000 A AC Resolution 1 A AC Accuracy ±(2.8 % + 5 digits) Overload protection 1000 A AC/DC Flexible clamp meter(50 ... 400 Hz) Measuring range 30.00 A AC Resolution 0.01 A AC Accuracy ±(3.0 % + 5 digits) Measuring range 300.0 A AC Resolution 0.1 A AC Accuracy ±(3.0 % + 5 digits) Measuring range 3000 A AC Resolution 1 A AC Accuracy ±(3.0 % + 5 digits) Overload protection 3000 A AC/DC The accuracy relates to a measuring range of 10 ... 100 %with a sine wave. Resistance Measuring range 600.0 Ω Resolution 0.1 Ω Accuracy ±(1.0 % + 10 digits) Measuring range 6.000 kΩ Resolution 0.001 kΩ Accuracy ±(1.5 % + 5 digits) Measuring range 60.00 kΩ Resolution 0.01 kΩ Accuracy ±(1.5 % + 5 digits) Measuring range 600.0 kΩ Resolution 0.1 kΩ Accuracy ±(1.5 % + 5 digits) Measuring range 6.000 MΩ Resolution 0.001 MΩ Accuracy ±(2.5 % + 5 digits) Measuring range 60.00 MΩ Resolution 0.01 MΩ Accuracy ±(3.5 % + 10 digits) Overvoltage protection 1000 V AC/DC Continuity test Signal