Features Double-Circuit Limit Switch Durable Aluminum Outer Casing Encloses the Components IP66 Rated for Protection Against Water, Oil, and Dust Capable of Handling Currents Up to 10 Amps Adjustable Rotary Lever Actuator to Suit Specific Applications Equipped with a Built-In Contact Stand Featuring a Double-Spring Mechanism for Extended Service Life Ratings Rated Voltage Non-inductive load(A) Inductive load(A) Resistance load Lamp Load Inductive load Motor Load NC NO NC NO NC NO NC NO 125VAC 10 3 1.5 10 5 2 250VAC 5 2 1 5 3 1 480VAC 3 1.5 0.8 3 1.5 0.8 600VAC 1 1 0.5 1.5 1 0.5 8VDC 10 6 3 10 6 14VDC 10 6 3 10 6 30VDC 6 4 3 6 4 125VDC 0.8 0.2 0.2 0.8 0.2 250VDC 0.4 0.1 0.1 0.4 0.1 Contact Form OpenOpen CloseClose Notes: Inductive load has a power factor of 0.4 min(AC)and a time constant of 7 ms. Lamp load has inrush current of 10 times the steady-state current, while motor load has an inrush current of 6 times the steady-state current. Characteristics Operation speed 1mm-2m/s(TLC2) 1mm-2m/s Operation Frequency 120 Mechanical:120operations/minute. Electrical:30operations/minute Contact resistance 15MΩ 15MΩ Max (initial value) Insulation resistance 100MΩ (500VDC) 100MΩ min (at 500VDC) Dielectric strength 1000VAC , 50/660Hz 1000VAC , 50/660Hz For 1 minute between terminals of the same polarity 1500VAC , 50/660Hz 1500VAC , 50M660Hz For 1 minute between current-carrying and non current-carrying metal parts 1500VAC , 50/660Hz 1500VAC , 50M660Hz For 1 minute between each terminal and ground Vibration 10-50Hz,1.5mm 10-50Hz,1.5mm double amplitude Shock 1000m/Sec²(100G'S) Mechanical durability:1000m.Sec² (about 100G' S) 300m/Sec² (30G'S) Malfunction:300m.Sec² (about 30G' S) Ambient temperature -10-+80°C Use:-10-+80°C Humidity 95%RH