This XPSBF safety module is for electrical monitoring of two-hand control stations. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for two-hand control stations, designed to protect operators from sustaining hands injury. It has additional solid-state output for communication with PLCs about safety status of your process.Main Characteristic Value(s) Range of Product Preventa Safety automation Product or Component Type Preventa safety module Safety module name XPSBF Safety module application For electrical monitoring of two-hand control stations Function of module Monitoring two-hand control station and a foot switch Safety level Can reach PL e/category 4 EN/ISO 13849-1Can reach SILCL 3 EN/IEC 62061 Safety reliability data DC > 99 % EN/ISO 13849-1MTTFd = 50.1 years EN/ISO 13849-1PFHd = 1.3E-8 1/h EN/IEC 62061 Connections - terminals Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable endCaptive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable endCaptive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezelCaptive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable endCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable endCaptive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezelCaptive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel Output type Relay, 2 NO, volt-free Number of additional circuits 2 solid state outputs [Us] Rated Supply Voltage 24 V DC - 20...20 % Complementary Characteristic Value(s) Synchronisation time between inputs 0.5 s Power Consumption in W 2.5 W Input protection type Internal, electronic Number of Inputs 1 NC + NO Input compatibility Two-hand control EN 574/ISO 13851-III C [Uc] control circuit voltage 24 V DC Breaking capacity 180 VA holding AC-15 C300 relay output1800 VA inrush AC-15 C300 relay output Breaking capacity 20 mA 24 V solid state output circuit1.5 A 24 V DC-13)50 ms relay output Output thermal current 4.2 A per relay relay output [Ith] conventional free air thermal current 8.4 A Associated fuse rating 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 2006 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 Minimum output current 10 mA relay output Minimum output voltage 17 V relay output Maximum response time on input open 20 ms [Ui] rated insulation voltage 300 V 2)IEC 60947-5-1300 V 2)DIN VDE 0110 part 1 [Uimp] rated impulse withstand voltage 4 kV III IEC 60947-5-14 kV III DIN VDE 0110 part 1 Local signalling 3 LEDs Current consumption 8 mA 24 V DC on power supply Mounting Support 35 mm symmetrical DIN rail Product Weight 0.33 lb(US) (0.15 kg)