Product characteristics Probe length L [mm] 15...156 Process connection Ø 10 mm Application System gold-plated contacts Installation Sensor suitable for clamp fitting Media Liquids; Gases Medium temperature [°C] -20...70 Pressure rating [bar] 30 Liquids Installation Sensor suitable for clamp fitting Medium temperature [°C] -20...70 Gases Medium temperature [°C] -20...70 Electrical data Connection to control monitor VS2000 Exi (PTB 01 ATEX 2075) Measuring/setting range Probe length L [mm] 15...156 Liquids Setting range [cm/s] 3...300 Greatest sensitivity [cm/s] 3...60 Gases Setting range [cm/s] 200...3000 Greatest sensitivity [cm/s] 200...800 Accuracy / deviations Max. temperature gradient of medium [K/min] 15 Reaction times Response time [s] 1...10 Liquids Response time [s] 1...10 Gases Response time [s] 1...10 Operating conditions Ambient temperature [°C] -20...70 Protection IP 67 Tests / approvals Approval DMT 03 ATEX E091; IECEX BVS 06.0007 ATEX marking II 2G Ex ia IIC T4 Gb Shock resistance DIN IEC 68-2-27 40 g (11 ms) Vibration resistance DIN IEC 68-2-6 10 g (55...2000 Hz) MTTF [years] 8272 Safety classification Max. internal capacitance [nF] 0.4 Max. internal inductance [µH] 2 Temperature class T4 Mechanical data Weight [g] 123 Dimensions [mm] Ø 10 Material stainless steel (1.4404 / 316L) several parts, welded Materials (wetted parts) stainless steel (1.4404 / 316L) several parts, welded Process connection Ø 10 mm Accessories Accessories (optional) Clamp adapter: R 1/2, E40160 Clamp adapter: 1/2" NPT, E40174 Remarks Remarks In principle, the type test according to 94/9/EC (ATEX) only takes atmospheric conditions into account (0.8...1.1 bar). For pressures outside this range use must be assessed and approved by the user. Adhere to the operating instructions and the type test certificate. Pack quantity 1 pcs. Electrical connection Connection Connector: 1 x M12; coding: A; Contacts: gold-plated; Maximum cable length: 100 m