Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Measuring range 80...9600 gph 1.3...160 gpm Process connection threaded connection G 2 external thread DN50 flat seal Application System gold-plated contacts Application Totalizer function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media Conductive liquids; water; water-based media Note on media conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) Medium temperature [°F] 14...194 Pressure rating [bar] 16 Pressure rating [psi] 232 MAWP (for applications according to CRN) [bar] 16 Electrical data Operating voltage [V] 18...32 DC; (to SELV/PELV) Current consumption [mA] < 150 Protection class III Reverse polarity protection yes Power-on delay time [s] 5 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1 Inputs Inputs counter reset Outputs Total number of outputs 2 Output signal switching signal; analog signal; pulse signal; frequency signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2 Permanent current rating of switching output DC [mA] 250; (per output) Number of analog outputs 1 Analog current output [mA] 4...20; (scalable) Max. load [Ω] 500 Analog voltage output [V] 0...10; (scalable) Min. load resistance [Ω] 2000 Pulse output flow rate meter Short-circuit protection yes Type of short-circuit protection yes (non-latching) Overload protection yes Frequency of the output [Hz] 0.1...10000 Measuring/setting range Measuring range 80...9600 gph 1.3...160 gpm Display range -11520...11520 gph -190...190 gpm Resolution 5 gph 0.1 gpm Set point SP 130...9600 gph 2.1...160 gpm Reset point rP 80...9550 gph 1.3...159.2 gpm Analog start point ASP 0...7680 gph 0...128 gpm Analog end point AEP 1920...9600 gph 32...160 gpm Low flow cut-off LFC < 240 gph < 4 gpm In steps of 5 gph 0.1 gpm Measuring dynamics 1:120 Volumetric flow quantity monitoring Pulse value 0.02...160 E06 gal In steps of 0.02 gal Pulse length [s] 0,008...2 Temperature monitoring Measuring range [°F] -4...176 Display range [°F] -40...212 Resolution [°F] 0.5 Set point SP [°F] -2...176 Reset point rP [°F] -3...175 Analog start point [°F] -4...140 Analog end point [°F] 32...176 In steps of [°F] 0.5 Accuracy / deviations Flow monitoring Accuracy (in the measuring range) ± (0,8 % MW + 0,5 % MEW) Repeatability ± 0,2% MEW Temperature monitoring Temperature drift ± 0,0185 °F / K