Product characteristics Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Measuring range -30...300 °C -22...572 °F Communication interface IO-Link Application Application asphalt; coated metal; liquids; glass; rubber; wood; ceramics; plastics; lacquers; food products; paper; fabric Electrical data Operating voltage [V] 18...32 DC; (to SELV/PELV) Current consumption [mA] < 50 Min. insulation resistance [MΩ] 100; (50 V DC) Protection class III Reverse polarity protection yes Power-on delay time [s] < 1 Inputs / outputs Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Inputs Test input type 3 (IEC 61131-2) Outputs Total number of outputs 2 Output signal switching signal; analog signal; IO-Link; (configurable) Electrical design PNP Number of digital outputs 1 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 150 Number of analog outputs 1 Analog current output [mA] 4...20 Max. load [Ω] 500 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Short-circuit proof yes Overload protection yes Monitoring range Wave length range [µm] 8...14 Measuring/setting range Measuring range -30...300 °C -22...572 °F Set point SP -29...300 °C -20.2...572 °F Reset point rP -30...299 °C -22...570.2 °F Analog start point -30...250 °C -22...482 °F Analog end point 20...300 °C 68...572 °F In steps of 0.5 °C 1 °F Resolution Resolution of switching output [K] 0.5 Resolution of analog output [K] 0.2; (+ 0.03 % of the set measuring span) Resolution of display [K] 0.5 Accuracy / deviations Accuracy [K] < ± 1 %; (of measured value, min. 2 K (degree of emission = 1, T = 23 °C)) Repeatability [K] 1 Reaction times Response time [ms] 100 Software / programming Adjustment of the switch point Programming buttons Parameter setting options Analog range; normally open / closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 SIO mode yes Required master port class A Process data analog 16 Process data binary 1 Min. process cycle time [ms] 3.6 Supported DeviceIDs Type of operation DeviceID default 716 Operating conditions Ambient temperature [°C] 0...65 Storage temperature [°C] -20...80 Max. relative air humidity [%] 95; (non condensing) Protection IP 65 Tests / approvals EMC DIN EN 61000-6-2 DIN EN 61000-6-4 Shock resistance