Product characteristics Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Measuring range 250...1600 °C 482...2912 °F Communication interface IO-Link Application Application tempering temperatures; glass melting; graphite; ceramics; metals; forging; sintering; heat treatment; rolling Electrical data Operating voltage [V] 18...32 DC; (to SELV/PELV) Current consumption [mA] < 50 Min. insulation resistance [MΩ] 100; (50 V DC) Protection class III Reverse polarity protection yes Power-on delay time [s] < 1 Inputs / outputs Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Inputs Test input type 3 (IEC 61131-2) Outputs Total number of outputs 2 Output signal switching signal; analog signal; IO-Link; (configurable) Electrical design PNP Number of digital outputs 1 Output function normally open / closed; (configurable) Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 150 Number of analog outputs 1 Analog current output [mA] 4...20 Max. load [Ω] 500 Short-circuit protection yes Type of short-circuit protection yes (non-latching) Short-circuit proof yes Overload protection yes Monitoring range Wave length range [µm] 1...1.7 Measuring/setting range Measuring range 250...1600 °C 482...2912 °F Set point SP 251...1600 °C 484...2912 °F Reset point rP 250...1599 °C 482...2910 °F Analog start point 250...1400 °C 482...2552 °F Analog end point 450...1600 °C 842...2912 °F In steps of 1 °C 1 °F Resolution Resolution of switching output [K] 1 Resolution of analog output [K] 0.2; (+ 0.03 % of the set measuring span) Resolution of display [K] 1 Accuracy / deviations Accuracy [K] < ± 0,5 %; (of measured value, min. 4 K (degree of emission = 1, T = 23 °C)) Repeatability [K] 1 Reaction times Response time [ms] 2; (T > 600 °C) Software / programming Adjustment of the switch point Programming buttons Parameter setting options Analog range; normally open / closed; switch-on/switch-off delay; Damping; Peakhold; emissivity; simulation function Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 SIO mode yes Required master port class A Process data analog 16 Process data binary 1 Min. process cycle time [ms] 3.6 Supported DeviceIDs Type of operation DeviceID default 717 Operating conditions Ambient temperature [°C] 0...65 Storage temperature [°C] -20...80 Max. relative air humidity [%] 95; (non condensing) Protection IP 65 Tests / approvals EMC DIN EN 61000-6-2 DIN EN 61000-6-4 Shock resistance